Why blast-resistant
Force protection, engineered to spec.
Blast-resistant glazing keeps people safe when a threat hits the facade — absorbing energy, holding the glass in the frame, and resisting forced entry. We install DoD- and GSA-compliant systems engineered to UFC 4-010-01 and ISC criteria, with the laminated and anchored detailing that makes the rating real.
Why it works
What blast-resistant systems deliver.
Protection, compliance, and performance for secure federal and military facades.
Blast protection
Absorbs explosive energy and retains glazing to protect occupants inside.
Forced-entry resistant
Laminated, anchored assemblies resist break-in and ballistic threats where specified.
DoD & GSA compliant
Systems engineered and tested to federal physical-security standards.
Engineered anchoring
Frames and anchors sized to transfer blast load into the structure.
Daylight retained
Protection without bunkering — secure facilities stay open and bright.
UFC & ISC criteria
Installed per UFC 4-010-01 and ISC Physical Security Criteria.
Cleared crews
Background-cleared installers with secure base-access experience.
Schedule-managed
Lead times confirmed at bid and coordinated with federal PMs.

Capability 02
Blast & ballistic storefronts and windows.
We provide blast- and ballistic-rated window and storefront systems engineered to protect against forced entry, active shooter threats, and explosive impacts.
- San Diego’s go-to installer for military-grade glazing systems
- Products from Oldcastle BuildingEnvelope, Assa Abloy, and Armortex
- UL 752, ASTM F1642, and NIJ-rated glazing systems
- Installed per UFC 4-010-01 and ISC Physical Security Criteria
- Proven protection for facilities near 32nd Street Naval Station and MCAS Miramar

Built to the threat
Engineered, tested, and installed to spec.
Blast resistance lives in the whole assembly — glass, frame, anchors, and the structure behind it. We install DoD- and GSA-compliant systems engineered to the project’s threat level and set per federal criteria.
- DoD- and GSA-compliant aluminum systems (Arcadia)
- Blast/impact-rated windows and curtain wall (EFCO)
- Certified blast-resistant storefront and curtain wall (Kawneer)
- Installed per UFC 4-010-01 and ISC Physical Security Criteria
- Laminated, forced-entry, and ballistic glazing options
Vendor strengths
Which blast-resistant system fits.
Three DoD/GSA-compliant lines, each with its sweet spot. We’ll match the system to the threat level, facade, and spec.
| Feature | Arcadia | EFCOMost specified | Kawneer |
|---|---|---|---|
| Strength | DoD/GSA aluminum systems | Blast/impact windows & curtain wall | Certified blast storefront & curtain wall |
| Best for | Federal aluminum facades | Windows + full curtain wall | Storefront + curtain wall |
| Compliance | DoD · GSA | Blast/impact-rated | Certified blast-resistant |
| Typical application | Base & federal buildings | Mixed window + facade | Entrances & facades |
All three are installed per UFC 4-010-01 and ISC criteria. Final selection depends on the project’s threat assessment and architectural spec.
FAQ
Common questions on blast-resistant products.
Quick answers for contracting officers, federal PMs, and GCs — anything else, we’ll cover at the site walk.
Which standards do you build to?
What’s the difference between blast and impact rating?
Can blast-resistant glazing still look like normal windows?
Are your crews cleared for base access?
Do you provide engineering and submittals?
Can you combine blast glazing with SCIF and hollow metal?
Cleared for your project
Ready to scope blast-resistant glazing?
Talk with our federal project lead. We’ll review the threat level and spec, confirm clearance and compliance fit, and turn around an accountable bid.